Zettler Magnetics, a Zettler Group division, provides application-engineering, sales, distribution and customer service for a wide variety of top quality transformers and magnetics components. We cater to a broad spectrum of customers in diverse industries and across many applications. Zettler Magnetics Transformers include epoxy sealed power transformers, open frame, low profile, switching transformers and chokes, while toroids include current sensing, zero phase current sensor, current transformers, PFC chokes and large power line filter inductors. Zettler Magnetics has the design and manufacturing capability to provide custom designs for the most specialized applications. Our sales, marketing, technical support, quality control and customer service departments work closely with our team of experienced design engineers at our manufacturing plant to help define the needs of our customers, and to provide optimal technical solutions for the most demanding application requirements.

HP02SXX00WI Series ●

HP02SXX00WI Series ● ● ● ● ● ● ● ● ● ● ● ● ● ● FEATURES PCB mounted switching power module AC input voltage range: 85VAC~305VAC DC input voltage range: 100VDC~430VDC Ambient temperature range: -25~85 Storage temperature range: -40~105 Leakage current (Input :305VAC):0.25mA Isolation voltage: Input –Output≥3600VAC 60S Insulation Resistance: Input –Output 500VDC≥100M Ohms MTBF:1000Khrs Min MIL-HDBK-217F25 Compact size, easy installation High efficiency low standby power consumption0.15W, Environment-friendly Built-in output over current protection, over-voltage protection, short circuit protection Built-in EMI filter components, comply with the EN55032 class B standard ClassConstruction 应 用 APPLICATIONS 型 号 列 表 MODEL LIST 产 品 特 点 可 用 在 PCB 上 插 装 的 电 源 模 块 交 流 输 入 电 压 范 围 : 85VAC~305VAC 直 流 输 入 电 压 范 围 : 100VDC~430VDC 工 作 环 境 温 度 范 围 : - 25℃ ~ 85℃ 储 存 温 度 范 围 : - 40℃ ~105℃ 漏 电 流 ( 输 入 电 压 :305VAC):

电 性 能 ELECTRICAL SPECIFICATION Model No. / 型 号 HP02SXX00WI Rated Voltage / 额 定 电 压 100 -277VAC Voltage Range / 输 入 电 压 范 围 85 -305VAC or 100 -430VDC Frequency (Hz) / 输 入 频 率 范 围 47 - 63 Hz Input 输 入 参 数 Current (Full load) / 输 入 电 流 115VAC 45mA 230VAC 30mA 277VAC 15mA Inrush Current (40ms/230VAC,12ms/115VAC ≥120%Io Self-recovery Hiccup ,continuous ,short capable, self-recovery Operating Temperature / 工 作 温 度 -25°C~+85°C @Free air convection Environment 环 境 Physical 外 观 结 构 Safety & EMC 安 全 认 证 及 电 磁 兼 容 Reliability Requirement 可 靠 性 要 求 Operating Humidity / 工 作 湿 度 Storage Temperature / 存 储 温 度 Storage Humidity / 存 储 湿 度 Temperature Coefficient/ 温 度 漂 移 系 数 Case Material / 外 壳 材 质 Weight / 产 品 净 重 Dielectric Strength / 绝 缘 强 度 Safety Standards / 安 全 标 准 EMI / 电 磁 兼 容 EMS (Noise Immunity)/ 电 磁 抗 干 扰 MTBF/ 平 均 故 障 间 隔 时 间 Burn-In Test/ 老 化 测 试 10~90% RH -40°C ~ +105°C 5~95% RH ( No Condensing) at full load ±0.03%/°C(0~85℃) Plastic (UL 94V-0 rated) 20g(ref.) I/P-O/P : 3600VAC Compliance With UL/EN62368-1 ,EN61558-2-16 Compliance With EN55032 Class B, EN61000-3-2, EN61000-3-3 Need to add external EMC component Compliance With EN55035 (Refer to the Schematic) 1000Khrs Min MIL-HDBK-217F(25℃) The unit shall be burned in for 2~4 Hours under 264Vac input and with full load at 25 11

Phone: 089 - 800 97-0 | E-Mail: office[@]zettlerelectronics.com | Junkersstr. 3 82178 Puchheim